基于ATmega32U4单片机的液体变焦透镜控制系统
DOI:
CSTR:
作者:
作者单位:

1.南京邮电大学微流控光学技术研究中心 南京 210023; 2.西南技术物理研究所 成都 610041

作者简介:

通讯作者:

中图分类号:

TN710

基金项目:

国家自然科学基金(12273085)项目资助


Liquid zoom lens control system based on ATmega32U4 microcontroller
Author:
Affiliation:

1.Center of Optofluidic Technology, Nanjing University of Posts and Telecommunications,Nanjing 210023, China; 2.Southwest Institute of Technical Physics,Chengdu 610041, China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    针对传统液体透镜控制系统成本高及不能满足个性化定制等问题,开发了一款用于液体透镜自动调焦的控制系统。系统选择ATmega32U4单片机为主控芯片,选择LTC2662芯片和H桥电路作为电流输出模块用于控制液体透镜实现变焦,并提供手动和自动两种操作模式供用户选择。该系统电流输出模块可输出DC -300~300 mA的稳定工作电流,平均误差0.64%,电流稳定度为0.327 7%;而焦距控制软件的自动调焦平均耗时约1.3 s,图像分辨率可达45.3 lp/mm。与现有的液体透镜控制系统相比,该系统实现了对液体透镜焦距的自动调节,操作简单、性能稳定、成本较低,为液体透镜提供了更加灵活和个性化的定制选项。

    Abstract:

    Aiming at the high cost of the traditional liquid lens control system and the inability to meet the problems of personalised customisation, a control system for automatic focusing of liquid lenses is developed. The system selects ATmega32U4 microcontroller as the main control chip, LTC2662 chip and H-bridge circuit as the current output module for controlling the liquid lens to achieve zoom, and provides two operation modes, manual and automatic, for users to choose. The current output module of this system can output a stable working current of DC -300~300 mA, with an average error of 0.64% and a current stability of 0.327 7%; and the average time consumed by the auto-focusing of the focus control software is about 1.3 s, with an image resolution of up to 45.3 lp/mm. Compared with the existing liquid lens control system, this system realizes the automatic adjustment of the focus of the liquid lens, which is simple in operation, stable in performance, and low in cost. Compared with the existing liquid lens control system, this system can automatically adjust the focal length of the liquid lens with simple operation, stable performance and lower cost, providing more flexible and personalised customisation options for liquid lenses.

    参考文献
    相似文献
    引证文献
引用本文

党嘉祎,赵瑞,代俊,任驹,王杨.基于ATmega32U4单片机的液体变焦透镜控制系统[J].电子测量技术,2024,47(22):25-30

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2025-01-16
  • 出版日期:
文章二维码